GlideGet the app

Free tools › GMI calculator

GMI calculator

Glucose Management Indicator from your average CGM glucose. Runs in your browser; nothing is sent anywhere.

7.0%53 mmol/mol

What GMI is

GMI is the A1c you would expect from your average CGM glucose. The formula was fitted by Bergenstal and colleagues in 2018 from paired CGM and lab A1c data, and it replaced the older "estimated A1c" label because the two numbers are not the same thing: A1c is a lab measure of red blood cells over about three months, and GMI is a calculation from sensor readings over the period you pick. In that dataset, 28% of people had a GMI and a lab A1c that differed by 0.5 points or more.

The formula

The international consensus on CGM metrics (Battelino et al., 2019) recommends at least 14 days of data with the sensor worn 70% of the time before reading a GMI as a summary.

Quick table

Average mg/dLAverage mmol/LGMI
1005.65.7%
1267.06.3%
1407.86.7%
1548.57.0%
18310.27.7%
21211.88.4%
24013.39.1%

Glide's Insights tab shows the same GMI for the last 14 days beside time in range and GRI, computed with this formula from the readings it stores in mg/dL.

GMI vs A1c chart

A GMI is the A1c your average glucose predicts. Your lab A1c can come out above or below it. In the 2018 dataset, about 7 in 10 people had a lab A1c less than 0.5 points from their GMI. The last column shows that band.

GMIAverage mg/dLAverage mmol/LLab A1c, 7 in 10 people
6.0%1126.25.6–6.4%
6.4%1297.26.0–6.8%
6.5%1337.46.1–6.9%
7.0%1548.56.6–7.4%
7.5%1759.77.1–7.9%
8.0%19610.97.6–8.4%
8.5%21712.08.1–8.9%
9.0%23813.28.6–9.4%
10.0%28015.59.6–10.4%

A GMI of 6.4% means an average glucose near 129 mg/dL (7.2 mmol/L). The 2019 consensus sets a time in range above 70% as the goal for most people with type 1, and ties it to an A1c near 7%. To go from time in range to an A1c, use the time in range to A1c calculator.